Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
1.
Rev. bras. anestesiol ; 66(4): 363-368, tab, graf
Article in English | LILACS | ID: lil-787615

ABSTRACT

Abstract Background and objective: This was a prospective, randomized clinical study to compare the success rate of nasogastric tube insertion by using GlideScopeTM visualization versus direct MacIntosh laryngoscope assistance in anesthetized and intubated patients. Methods: Ninety-six ASA I or II patients, aged 18-70 years were recruited and randomized into two groups using either technique. The time taken from insertion of the nasogastric tube from the nostril until the calculated length of tube had been inserted was recorded. The success rate of nasogastric tube insertion was evaluated in terms of successful insertion in the first attempt. Complications associated with the insertion techniques were recorded. Results: The results showed success rates of 74.5% in the GlideScopeTM Group as compared to 58.3% in the MacIntosh Group (p = 0.10). For the failed attempts, the nasogastric tube was successfully inserted in all cases using rescue techniques. The duration taken in the first attempt for both techniques was not statistically significant; Group A was 17.2 ± 9.3 s as compared to Group B, with a duration of 18.9 ± 13.0 s (p = 0.57). A total of 33 patients developed complications during insertion of the nasogastric tube, 39.4% in Group A and 60.6% in Group B (p = 0.15). The most common complications, which occurred, were coiling, followed by bleeding and kinking. Conclusion: This study showed that using the GlideScopeTM to facilitate nasogastric tube insertion was comparable to the use of the MacIntosh laryngoscope in terms of successful rate of insertion and complications.


Resumo Justificativa e objetivo: Este foi um estudo clínico prospectivo e randômico para comparar a taxa de sucesso da inserção de sonda nasogástrica (NG) com as técnicas de visibilização guiada pelo laringoscópio GlideScope® versus guiada pelo laringoscópio MacIntosh em pacientes anestesiados e intubados. Métodos: Foram recrutados 96, ASA I ou II, entre 18-70 anos, e divididos randomicamente em dois grupos, com uma ou outra técnica. Foi calculado o tempo transcorrido desde a inserção da sonda NG, da narina até a inserção do comprimento calculado da sonda. A taxa de sucesso de inserção da sonda NG foi avaliada quanto à inserção bem-sucedida na primeira tentativa. As complicações associadas às técnicas de inserção foram registradas. Resultados: Os resultados mostraram taxas de sucesso de 74,5% para o grupo GlideScope® em comparação com 58,3% para o grupo MacIntosh (p = 0,10). Para as tentativas que falharam, a sonda NG foi inserida com sucesso em todos os casos, com as técnicas de resgate. A duração da primeira tentativa para ambas as técnicas não foi estatisticamente significativa: 17,2 ± 9,3 segundos no Grupo A e 18,9 ± 13,0 segundos no Grupo B (p = 0,57). No total, 33 pacientes desenvolveram complicações durante a inserção da sonda NG: 39,4% no Grupo A e 60,6% no Grupo B (p = 0,15). As complicações mais comuns ocorridas foram enrolamento, seguido de sangramento e dobradura. Conclusão: Este estudo mostrou que o uso do GlideScope® para facilitar a inserção de sonda nasogástrica foi comparável ao uso do laringoscópio MacIntosh quanto à taxa de sucesso de inserção e às complicações.


Subject(s)
Humans , Male , Female , Adolescent , Adult , Aged , Young Adult , Laryngoscopes , Intubation, Gastrointestinal/instrumentation , Intubation, Gastrointestinal/methods , Intubation, Intratracheal , Laryngoscopy/methods , Time Factors , Single-Blind Method , Prospective Studies , Equipment Design , Anesthesia , Middle Aged , Nasal Cavity
2.
Rev. bras. anestesiol ; 66(3): 259-264, May.-June 2016. tab
Article in English | LILACS | ID: lil-782892

ABSTRACT

ABSTRACT BACKGROUND AND OBJECTIVES: Combined spinal-epidural (CSE) has become an increasingly popular alternative to traditional labour epidural due to its rapid onset and reliable analgesia provided. This was a prospective, convenient sampling study to determine the effects of CSE analgesia on labour outcome. METHODS: One hundred and ten healthy primigravida parturients with a singleton pregnancy of ≥37 weeks gestation and in the active phase of labour were studied. They were enrolled to the CSE (n = 55) or Non-CSE (n = 55) group based on whether they consented to CSE analgesia. Non-CSE parturients were offered other methods of labour analgesia. The duration of the first and second stage of labour, rate of instrumental vaginal delivery and emergency cesarean section, and Apgar scores were compared. RESULTS: The mean duration of the first and second stage of labour was not significantly different between both groups. Instrumental delivery rates between the groups were not significantly different (CSE group, 11% versus Non-CSE group, 16%). The slightly higher incidence of cesarean section in the CSE group (16% versus 15% in the Non-CSE group) was not statistically significant. Neonatal outcome in terms of Apgar score of less than 7 at 1 and 5 min was similar in both groups. CONCLUSION: There were no significant differences in the duration of labour, rate of instrumental vaginal delivery and emergency cesarean section, and neonatal outcome in parturients who received compared to those who did not receive CSE for labour analgesia.


RESUMO JUSTIFICATIVA E OBJETIVOS: A analgesia combinada raquiperidural (RP) tornou-se uma opção cada vez mais popular para o trabalho de parto tradicional devido ao seu rápido início de ação e ao resultado confiável. Este foi um estudo prospectivo de amostragem conveniente para determinar os efeitos da RP sobre o desfecho do parto. MÉTODOS: Foram incluídas 110 parturientes primigestas saudáveis, com gestação única de ≥ 37 semanas e na fase ativa do trabalho de parto. As pacientes foram designadas para os grupos RP (n = 55) ou não RP (n = 55) com base em seus consentimentos para a analgesia combinada RP. As parturientes do grupo não RP receberam outros métodos de analgesia para o parto. As durações do primeiro e segundo estágio do trabalho de parto, as taxas de parto vaginal instrumental e cesariana de emergência e os escores de Apgar foram comparados. RESULTADOS: A média de duração do primeiro e segundo estágio do trabalho de parto não foi significativamente diferente entre os dois grupos. As taxas de parto instrumental não foram significativamente diferentes entre os grupos, RP (11%) versus não RP (16%). A incidência ligeiramente maior de cesariana no grupo RP (16% versus 15% no não RP) não foi estatisticamente significativa. O desfecho neonatal em termos de índice de Apgar foi inferior a 7. CONCLUSÃO: Não houve diferenças significativas em relação à duração do trabalho, às taxas de parto vaginal instrumental e cesariana de emergência e ao desfecho neonatal em parturientes que receberam RP para analgesia de parto em comparação com aquelas que não receberam.


Subject(s)
Humans , Female , Pregnancy , Adult , Young Adult , Labor, Obstetric , Analgesia, Epidural/methods , Analgesia, Obstetrical/methods , Delivery, Obstetric/statistics & numerical data , Anesthesia, Spinal/methods , Time Factors , Prospective Studies , Treatment Outcome , Drug Therapy, Combination
SELECTION OF CITATIONS
SEARCH DETAIL